Performance Contractors, Inc. v. Great Plains Stainless, Inc.
Filing
134
RULING denying 114 Motion to Allow Testing. Signed by Judge James J. Brady on 8/7/2013. (LLH)
UNITED STATES DISTRICT COURT
MIDDLE DISTRICT OF LOUISIANA
PERFORMANCE CONTRACTORS, INC.
CIVIL ACTION
VERSUS
NO. 11-485-JJB
GREAT PLAINS STAINLESS, INC.
RULING ON MOTION TO ALLOW TESTING
This matter is before the Court on a Motion to Allow Testing (Doc. 114) by the
Defendant, Great Plains Stainless, Inc. Performance Contractors, Inc. filed an opposition (Doc.
119). Great Plains filed a reply (Doc. 123) and a supplemental memorandum (Doc. 131).
Performance filed a sur-reply (Doc. 132). Jurisdiction is based upon Title 28 of the United States
Code, Section 1332. Oral argument is not necessary.
I.
Background
This suit arises out of the construction of the Plaquemine VCM Plant (“the Project”) in
Iberville Parish, Louisiana. Performance Contractors, Inc. entered into a contract with Shintech
Louisiana LLC calling for Performance to provide pipe fabrication and installation services for
the Project. Performance claims it issued Purchase Order No. 45140011 to Louisiana Chemical
Pipe Valve and Fitting, Inc. for duplex stainless steel piping and fittings for the Project.
Louisiana Chemical ordered the piping and fittings from Great Plains.
The ASTM
A815/A815M-09a (“A815”) standard applied to the fittings. A815, among other things, requires
heat treatment (annealing) and water quenching of 2205 duplex stainless steel.
ASTM
A815/A815M-09a, at 6.1 & table 2. A815 requires conformity with the ASTM A960/960M
(“A960”) standard.
ASTM A815/A815M-09a, at 2.1.
intermetallic phases or ferrite content.
1
A815 does not impose a limit on
Performance claims the fittings supplied by Great Plains were defective. This claim at
least partly arises from the finding of a cracked two inch tee fitting during hydrostatic testing.
The cracked tee and other fittings were submitted to Welding Testing Laboratories (“WTL”) for
analysis. WTL found a low ferrite content in the tee and concluded the fitting may have been
improperly annealed.
Performance filed this lawsuit asserting claims for redhibition and
products liability and seeking damages. Performance subsequently filed a Supplemental and
Amended Complaint (Doc. 29) asserting claims as the assignee of Louisiana Chemical’s rights
against Great Plains for redhibition, products liability, breach of contract, and bad faith and
misrepresentation.
Performance has since filed a Second Supplemental and Amending
Complaint (Doc. 111) to state a bad faith redhibition claim against Great Plains as a seller. All
claims in this lawsuit arise under Louisiana law.
Since the filing of the instant Motion, the Court ruled on a Daubert motion (Doc. 69) and
motion for summary judgment (Doc. 70) by Great Plains seeking to exclude at trial the evidence
of the Plaintiff’s experts, Gary Carinci, Ph.D., and Brian Soucy, P.E., strike their expert reports,
and have summary judgment granted in its favor because Performance cannot prove the products
in question are defective under the ASTM standards. The Daubert ruling made the following
holdings: (1) Performance cannot present the NACE standard or test results to show NACE
compliance was required or unsatisfied, or testify to such a conclusion; (2) to the extent Carinci’s
NACE test results show a ferrite content that, using the presented equation and multi-variable
regression analysis, shows non-compliance with the annealing and water quench requirements of
A815, these results will be allowed; (3) Performance and Carinci cannot present the ASTM
A923 Method A test results to show A923 compliance was required or unsatisfied or testify to
such a conclusion; (4) Carinci’s ASTM A923 Method A tests and results will be allowed; (5) the
2
results of Carinci’s ASTM A923 Method C tests and any related conclusions are excluded; (6)
Carinci’s E562 tests and results will not be excluded; (7) to the extent the tested fittings have
walls thin enough to require Rockwell C testing, Carinci’s Rockwell C test results will not be
excluded; (8) Carinci’s conversion of his Rockwell C test results to Brinell numbers is excluded;
(9) Carinci’s Brinell hardness test results are excluded; (10) to the extent Carinci’s test results
show higher levels of intermetallic phases or low levels of ferrite, his conclusion of improper
annealing will not be excluded; (11) Soucy’s testimony will not be excluded; (12) Soucy’s
opinion that Performance’s testing was reasonable is based on relevant factors; (13) the
testimony allowed by the Daubert ruling is not excluded under Federal Rule of Evidence 403;
and (14) summary judgment is inappropriate.
II.
Analysis
In the instant Motion, Great Plains seeks an order allowing it to conduct testing on a
select sampling of the duplex stainless steel parts removed and retained by Performance. Great
Plains argues it should be allowed to conduct testing if the Court’s Daubert ruling allows the
Plaintiff “to present evidence outside of its expert report at trial regarding the limit on
intermetallic phase levels,” because testing will have become relevant.1
Performance has not contended that A815 establishes a limit on ferrite content or
intermetallic phases, nor has the Court allowed evidence of any limit.
The evidence and
testimony allowed by the Daubert ruling have not “become” relevant. Carinci made conclusions
involving ferrite content, intermetallic phases, or microstructure multiple times during discovery.
Doc. 69-3, at 168; Doc. 86-3, at 2. Performance stated at Carinci’s deposition, taken October 23,
1
Great Plains’ briefs contain other arguments, but it concedes in its supplemental post-Daubert ruling memorandum
that this is its only remaining argument.
3
2012, that Great Plains could have access to the fittings “next week.” Doc. 119-2, at 2–3. Great
Plains could have performed testing during the allotted discovery period. Instead, it made the
strategic decision to challenge Carinci’s tests and results and not to perform testing. Great
Plains’ expert even stated at the Daubert hearing held May 13, 2013 that it would be
“extraordinarily redundant to do more testing.” Doc. 108, at 60. Great Plains’ expert report was
due August 15, 2012, and expert discovery ended November 30, 2012. Doc. 10, at 2. Great
Plains cannot now perform additional expert discovery because its strategy to completely
exclude Carinci’s tests and results failed. This is not a legitimate justification for delay in
waiting to conduct tests. Performance would be prejudiced by: having to undertake additional
discovery related to the testing, the potential motion practice which might follow, and further
delay in the hearing of its claims on the merits. Judicial economy would also be negatively
affected by the delay. Ample time was allotted for discovery and motion practice, and that time
has passed.
III.
Conclusion
Accordingly, Great Plains Stainless, Inc.’s Motion to Allow Testing (Doc. 114) is
DENIED.
Signed in Baton Rouge, Louisiana, on August 7, 2013.
JAMES J. BRADY, DISTRICT JUDGE
4
Disclaimer: Justia Dockets & Filings provides public litigation records from the federal appellate and district courts. These filings and docket sheets should not be considered findings of fact or liability, nor do they necessarily reflect the view of Justia.
Why Is My Information Online?