COMPLAINT against Detector Electronics Corporation, UTC Fire & Security Corporation, United Technologies Corporation ( Filing fee $ 350 receipt number 0540-2739937.), filed by Tex Pat, LLC. (Attachments: # 1 Exhibit A, # 2 Exhibit B, # 3 Exhibit C, # 4 Exhibit D, # 5 Exhibit E, # 6 Exhibit F, # 7 Civil Cover Sheet)(Ni, Hao)
Tex Pat, LLC v. United Technologies Corporation et al
Doc. 1 Att. 4
EXHIBIT D
Dockets.Justia.com
SPECIFICATION DATA
UV Flame Detector X2200
DESCRIPTION
F E AT u R E S
Y
Wa r r a n t Y
3
e
a
r
TheevolutioncontinueswiththenewX2200 UVFlameDetector.TheX2200isthemost advancedUVdetectormeetingstandardsand approvalsworldwide,combinedwithasuperior mechanicaldesign.Thedetectorisequipped withautomatic,manualandmagneticoitest capability.ThedetectorhasDivisionandZone explosion-proofratingsandissuitableforuseina varietyofapplications.
· · · · · · · · · · · · · · · · · · · · ·
Thestandardoutputconfigurationincludesfire,faultandauxiliary relays.Anoptional4to20mAoutputcanbeprovidedinaddition tothethreerelays.Amodelwithpulseoutputisavailable foreasyretrofittingintoexistingDet-Tronicscontrollerbased systems.Auxiliaryrelayand4to20mAoutputarenotavailable withthepulsemodel.AtricolorLEDonthedetectorfaceplate indicatesdetectorstatuscondition. TheX2200housingisavailableinaluminumorstainlesssteel, withNEMA4XandIP66rating. Typicalapplicationsinclude: -- Hydrogenstorage -- Munitions -- Silanestorage.
* oi is Detector Electronics' Trademark for its patented Optical Integrity Systems, U.S. Patent 3,952,196, United Kingdom Patent 1,534,969, CanadaPatent1,059,598. 2.2 ©Detector Electronics Corporation 2007
FM3260(2000). EM54-10Certified(VdS). ATEXDirectivecompliant. EQPmodelsavailable. Advancedsignalprocessing. Arc--unequaledfalsealarmrejection. Respondstoafireinthepresenceofmodulatedblackbody radiation(i.e.heaters,ovens,turbines)withoutfalsealarm. Highspeedcapability. Automatic,manualormagneticopticalintegrity(oi)testing --noexternaltestlamprequired. Easilyreplaceableoiplate. Fire,faultandauxiliaryrelaysstandard. MODBUSRS-485communication. 4to20mAisolatedoutput(optional). Pulseoutputforcompatibilitywithcontrollerbasedsystems (optional). TricolorLEDindicatesnormaloperation,fireandfault conditions. Mountingswivelallowseasysighting. Integralwiringcompartmentforeaseofinstallation. ClassAwiringperNFPA-72. MeetsNFPA-33responserequirementforunder0.5second (availablewhenmodelselected). RFIandEMCDirectivecompliant. Built-indatalogging/eventmonitoring.
4/07 90-1157
S P E C I F I C AT I O N S Operating Voltage Power Consumption Relays 24vdc.Operatingrangeis18to30vdc. 2.5watts@24vdcnominal. 7.6watts@30vdcwithEOLresistorinstalled. Contactsrated5amperesat30vdc. Certification FM ® FM ClassI,Div.1,GroupsB,C&D; IncreasedSafetyModel ClassII,Div.1,GroupsE,F,&G; 0539 II2GD ClassI,Div.2,GroupsA,B,C&D(T3); EExdeIICT5T6T86°C ClassII,Div.2,GroupsF&G(T3); DEMKO02ATEX132195 ClassIII. T6(Tamb=55°Cto+60°C). NEMA/Type4X. T5(Tamb=55°Cto+75°C). IP66. IECEx FlameproofModel CertificateofConformity 0539 II2GD IECExULD06.0018X EExdIICT5T6T86°C ExdIICT5-T6orExdeIICT5-T6 DEMKO02ATEX132195 T6(Tamb=55°Cto+60°C). T6(Tamb=55°Cto+60°C). T5(Tamb=55°Cto+75°C). T5(Tamb=55°Cto+75°C). IP66. Dimensions Dimensionsshownininches(centimeters).
APPROVED
APPROVED
--FormC(NOandNCcontacts) --normallyde-energized --latching/non-latching. Fault: --FormA(NOcontacts) --normallyenergized --latching/non-latching.
FireAlarm: Auxiliary*:
FM
APPROVED
--FormC(NOandNCcontacts) --normallyenergized --latching/non-latching.
FM
APPROVED
Current Output* (Optional) Temperature Range Humidity Range
420mA,withamaximumloopresistanceof500 ohmsfrom1819.9vdc,600ohmsfrom2030vdc. Operating: Storage: 40°Fto+167°F(40°Cto+75°C). 67°Fto+185°F(55°Cto+85°C).
0to95%relativehumidity,canwithstand100% condensinghumidityforshortperiodsoftime. TheX2200hasa90degreeconeofvisionwiththe highestsensitivitylyingalongitscentralaxis. 3years. Copper-freealuminumor316stainlesssteel. 3/4inchNPTor25mm. Aluminum: 6pounds (2.7kg). StainlessSteel: 10pounds (4.5kg).
4.7 (11.9)
Field of View Warranty Enclosure Material Conduit Entry Size Shipping Weight (Approximate) Response Characteristics
VeryHighSensitivity
A2142
9.7 (24.6)
4.8 (12.2)
Wiring
14AWG(2.08mm2)or16AWG(1.31mm2) shieldedcableisrecommended.
9 8 7 6 5
4-20 mA + 4-20 mA + REF COM FIRE N.O. FIRE N.C. FIRE COM FAULT N.O. FAULT 24 VDC + 24 VDC
19 18 17 16 15 14 13 12 11
4-20 mA 4-20 mA REF
SPARE SPARE COM AUX N.O. AUX N.C. AUX RS-485 A RS-485 B MAN Oi
29 28 27 26 25 24 23 22 21
A2061
Fuel n-Heptane Methane
Size 1x1foot
Distance Feet (M) 85(25.9)
Typical Response Time (Sec.) 3 2
Mode LowArc LowArc
4 3 2 1
32inchplume 100(30.5)
24 VDC
NOTE: RefertotheX2200instructionmanual(formnumber95-8549)fordetails regardingdetectorresponse.
WiringTerminalIdentificationforStandardX2200
*Auxiliaryrelayand4to20mAoutputarenotavailableonpulseoutputmodel.
G
T IS
ED ER
BY UL
AN
D
BS
Detector Electronics Corporation
6901West110thStreet·Minneapolis,Minnesota55438USA Operator:(952)941-5665or(800)765-FIRE CustomerService:(952)946-6491·Fax(952)829-8750 http://www.det-tronics.com·E-mail:detronics@detronics.com
I
RE
ISO 9001
REGIS
NO .
S REGI
TER ED FIR
TE
RED FI
RM
M
A 23
05 · NO. 25
82
6
Specificationssubjecttochangewithoutnotice.
Disclaimer: Justia Dockets & Filings provides public litigation records from the federal appellate and district courts. These filings and docket sheets should not be considered findings of fact or liability, nor do they necessarily reflect the view of Justia.
Why Is My Information Online?